In this paper we want to study effect of snow storm as abnormal weather on two unit similar cold standby system. In this system after snow storm rescue operation starts on failed unit during rescue operation first digging out start from the snow and then hospitalization of the system (human) starts as a repair. There is a single repairman with the system has different rates. The failure rate due to snow storm follow exponential distributions and different repair rates follow different rates follow different general time distributions. The system is analyzed by making use of semi-Markov process, regenerative point technique and the following measures of system effectiveness such as mean time to system failure, study state availability, busy period of the repairman, expected number of visit periods by repairman are obtained. Profit is also evaluated using the above measures. In the end, numerical result, various graphs have been plotted for a particular case and interesting explanations have been made.
1. Osaki, 1972, ―Reliability Analysis of a Two-Unit Standby-Redundant System with Preventive Maintenance, IEEE Transactions on Reliability, 21, pp. 24–29.
2. Taneja, G., Tuteja, R.K., and Arora, R.T., 1991, ―Analysis of Two-Unit System with Partial Failures and Three Types of Repair, Reliability Engineering and System Safety, 33, pp. 199-214.
3. Taneja, G., Tuteja, R.K., 1992,―Cost-benefit analysis of a two-server, two-unit, warm standby system with different types of failure, Microelectronics Reliability, 32, pp. 1353-1359
4. Subramanian R. ,Anantharaman V., 1995, ―Reliability Analysis Of A Complex Standby Redudent System, Reliability Engineering and System Safety, 48, pp. 57-70.
5. Singh, D. and Taneja,G., 2014, ―Comparative of a Power Plant comprising one steamturbine with respect to two types of inspection, IJSCE, 6, pp.331-338.
6. Goel L.R., Sharma G.C., Gupta R., 1985, ― Cost analysis of a two-unit cold standby system under different weather conditions, Microelectron Reliab, 25(4), pp. 655-659.
7. Goel L.R., Kumar A. and Rastogi A. K. 1985,―Stochastic Behaviour Of Man—Machine Systems Operating Under Different Weather Conditions, Microelectron Reliab, 25(1), pp. 87-91.
8. Gupta, R., and Goel, R., 1991, ― Profit analysis of a two-unit cold standby system with abnormal weather condition, Microelectronics Reliability, 31(1), pp. 1-5.
9. Malhotra R., Taneja G.,2015, ―Comparative study between a single unit system and a two –unit cold standby systemwith varying demand,Springer Plus, 4, pp.1-17
10. Taj, S.Z., Rizwan,S.M., Alkali,B.M., Harrison,D.K., Taneja G., 2017, ―Reliability analysis of a single machine subsystem of a cable plant with six maintenance categories, International Journal of Applied Engineering Research , 12(8), pp. 1752-1757.
Narender Singh, Dalip Singh, Ashok kumar Saini, "Cost Analysis of Two Identical Cold Standby System under the Influence of Snow Storm Causing digging out and Hospitalization," International Journal of Mathematics Trends and Technology (IJMTT), vol. 47, no. 3, pp. 192-202, 2017. Crossref, https://doi.org/10.14445/22315373/IJMTT-V47P525